Grid Demand UK

GitHub

How much electricity Great Britain is using, and what this site guessed before the official figure was published. Three views of the forecast (week, day, half-hour). Scores and checks sit in dropdowns under each chart. Model architecture, the data pipeline, and SHAP have their own tabs. The capture loop issues due forecasts on its own. The project is complete. Times are UK. The black line is only drawn after each half-hour has ended.

Black — what actually happened (official grid outturn) Red — the central forecast (most likely demand) Blue — a likely range (low to high). The black line should usually sit between them.

What the scores mean
This freeze
Scores for the forecast on the chart: only half-hours that already have a black official number.
Holdout
The last train’s validation window (about eight weeks). A different sample from the live freeze — that is the lab score, not today’s board.
n
How many half-hours already have an official number, so they can be scored. “Waiting” means none yet. On the holdout row it is the size of that train window.
MAE
Typical size of the miss, in megawatts. Average of how far the red line was from the black line. Lower is better.
RMSE
Like MAE, but larger misses count more. Square root of the mean squared miss, in megawatts.
WRMSSE
Error compared with copying last week. 1.0 = as good as paste-last-week. Below 1 beats that. Above 1 is worse.
Coverage
How often the black line landed between the two blue lines. About 80% is the aim.
Bias
Mean of official demand minus the red line. Negative means the guess was too high. Positive means it was too low.
Width
Average gap between the two blue lines across the whole issued forecast (including hours that have not finished yet). The week fan is meant to get wider later in the week, so that pulls this number up. MAE and coverage still use only finished half-hours (n).

Loading board…

Next week

Written each Monday at midnight UK time.

This chart is the last two days of last week (Saturday and Sunday), then this week from Monday, in time order. That keeps this week’s half-hours readable. If last week’s Monday freeze is still on disk, the pale lines are that forecast against the black official numbers. From this Monday the bright lines are this week’s forecast. Open Scores for this freeze vs holdout.

This week

Scores

This freeze scores only hours of this week that already have a black line. Holdout is the last train, not this week.

This freeze

Holdout (last train)

How this freeze did

Finished half-hours on this chart only. Outside band — actual missed the blue range. Lags — the demand reading at issue did not match the official figure. Large miss — red line more than about 1.5 GW out, but still inside the blues.

Next 24 hours

Written at midnight UK time.

The left side is yesterday’s London calendar day, from the first stored half-hour until midnight. A late freeze (for example issued at 9am) still stops at midnight; it does not run into today. From midnight the bright lines are today’s forecast. Open Scores for today vs holdout.

Today

Scores

This freeze is today. Holdout is the last train, not this morning.

This freeze

Holdout (last train)

How this freeze did

Finished half-hours on this chart only. Outside band — actual missed the blue range. Lags — the demand reading at issue did not match the official figure. Large miss — red line more than about 1.5 GW out, but still inside the blues.

A new guess every half-hour.

This chart is the last six hours, one guess per half-hour. The guess labelled 1:30 is for 1:00–1:30, and the black official number for that half-hour is drawn at 1:30 too (Insights stores it at 1:00). Pale red is what was written at the time. Dots are the live guess still waiting. Open Scores for this freeze vs holdout, and INDO lag check for the demand readings the model used.

Last six hours

Scores

This freeze is those finished half-hours. Holdout is the last train.

This freeze

Holdout (last train)

Target
The end of the half-hour being guessed. 1:30 means 1:00–1:30, matching the black line.
Live P50
The current red-line guess, in megawatts, for that target half-hour.
How this freeze did

Finished half-hours on this chart only. Outside band — actual missed the blue range. Lags — the demand reading at issue did not match the official figure. Large miss — red line more than about 1.5 GW out, but still inside the blues. Stale share is how often lag_1 disagreed with INDO on recent issues.

INDO lag check

The status line is a health check on the latest guess: last official outturn (and how old it is), the two most recent demand readings the model was given, and UK temperature. Green means those look complete; red means the guess was skipped or the inputs look wrong. The table is a short history. lag_1 is the latest demand the model used; INDO then is the official figure available at issue time; stale lags means those two disagreed, so the guess may be off.